English 中文

Bookmark and Share
login register Item:0
  • HOME
  • ABOUT US
  • PRODUCTS
  • APPLICATION
  • FACTORY SHOW
  • FEEDBACK
  • CONTACT US
  • DOWNLOAD
Solar Pumps System
Solar 220V Pumps Inverter
Solar 380V/480V Pump Inverter
Solar Pump Drive Cabinet
DC Voltage Booster
GPRS remote controller 
Solar Pumps 
Solar Panel 
24V/48V DC solar Pump Inverter
Solar Pumps System
Solar street light
OEM solar street light
IP54 IP65 Solar pump inver
SU10 Solar pump inverter
AC MOTOR DRIVE/VFD
Motor AC Drive
Soft Stater
Soft Starter
 Drives peripheral equipment
Filter
Braking Unit And Braking Resistor
Reactor
PV solar Combiner box
pv combiner box
Zundrive is a China top manufacturer of AC drives, variable speed drive, Solar Pump drive,Soft Stater,Booster, Speed Controller...  
Tel:86-0755-23283620, 
MP:86-13249062939
service@zundrive.com


  
Product center -->Index >  Drives peripheral equipment > Reactor > AC Input Reactor

AC Input Reactor

AC Input Reactor (ACR)

Products introduction:  
Line and Load Reactors
Line reactors (sometimes called line chokes) are a common power accessory for electronic variable speed drives. These components add an extra margin of protection for AC and DC drives.
Line reactors used on the input side of a drive protect the AC drive from transient overvoltage conditions typically caused by utility capacitor switching. Input line reactors also reduce the harmonics associated with AC drives, and are recommended for all installations.
  
Production  Application
•  Help meet IEEE 519 criteria by reducing harmonic distortion of the input line current.
• Improve input line current balance.
• Reduce nuisance drive over-voltage trips cause dby transient voltage spikes and power line notches.
• Protect input rectifiers from in-rush current cause dby sudden power line surges and sags.
• Extend the life of the DC bus capacitor bank by reducing the internal heating caused by ripplecurrent.
• Protect motor windings from long lead effects when used on the drive output.
 
Particularly apply of line reactor to the following cases:

1. Multiple frequency inverters in close parallel connection
2. Other devices produce interference to line power supply ( disturbance. Over voltage)
3. Non balance among phases of  line power supply 1.8% over than of the rated voltage)
4. Massive frequency inverter installed in the same grid.
5. Reduce CosØ and correct the overload capacitor, in case the power factor correction device are installed in system.
 
Technical Specification:

Work voltage: 220VAC to 1140VAC
Work current: 3A to 1600A
Insulation class: Class F, H
Voltage drop: Less than 4%,
Overload tolerance capability: 1.5% rated current for 60s.
Noise: Less than 65dB
Temperature rise:  less than 85℃.
Dielectric strength: steel core wiring 3000VAC/50Hz/50mA/10s.
Insulation resistor: 1000VDC insulation resistor ≥100MΩ.
Operation Environment: -10℃to 45℃, rated value won’t lower, when higher than 55℃, and every 1℃, the current will stop down 2%. Under sea level 2000m
No hazardous gas, no inflammables and explosives. With well-ventilated condition, ventilation devices shall be configured if installed in control panels.
 